Enhanced TDS
Identification & Functionality
- Chemical Family
- RTU Product Type
- Technologies
- Product Families
Features & Benefits
- Product Features
- Features and Benefits
- High-quality mechanical and electrical end properties, as well as very high crack resistance and excellent thermal cycling resistance.
- Especially suitable for the encapsulation of large metal parts.
- Good impregnation behavior for windings and laminations.
- Very good adhesion to metallic materials.
Applications & Uses
- Cure Method
- Product End Uses
- Markets
- Applications
- Application Information
Encapsulation and impregnation of sheets for magnetic cores.
Properties
- Physical Form
Safety & Health
- Handling Precautions
Protective clothing
Yes Gloves Essential Arm protector Recommended when skin contact likely
Goggestery diasses
Yes Respirator/dust mask
Recommended Skin protection before starting work
Apply barrier cream to exposed skin
Skin protection after washing
Apply barrier or nourishing cream
Skin protection cleansing of contaminated skin
Dab off with absorbent paper, wash with warm water and alkali-free soap, then dry with disposable towels. Do not use solvents
Clean shop requirements
Cover workbenches, etc. with light coloured paper. Use disposable breakers, etc.
Disposal of spillage
Soak up with sawdust or cotton waste and deposit in plastic-lined bin
Ventilation: of workshop
Renew air 3 to 5 times an hour
Ventilation: of workplace
Exhaust fans. Operatives should avoid inhaling vapours.
- First Aid Information
- Contamination of the eyes by resin, hardener or casting mix should be treated immediately by flushing with clean, running water for 10 to 15 minutes. A doctor should then be consulted.
- Material smeared or splashed on the skin should be dabbed off, and the contaminated area then washed and treated with a cleansing cream (see above). A doctor should be consulted in the event of severe irritation or burns. Contaminated clothing should be changed immediately.
- Anyone taken ill after inhaling vapours should be moved out of doors immediately.
- Industrial Hygiene
Mandatory and recommended industrial hygiene procedures should be followed whenever our products are being handled and processed.
Storage & Handling
- Storage Conditions
The components described in this user manual should be stored at 18-25°C, always tightly sealed and dry, preferably in the original containers. Under these conditions, the shelf life corresponds to the expiry date indicated on the product label. After this date, the product may only be processed further after re-analysis. Opened containers should be tightly closed immediately after use. For hazardous decomposition products in the event of a fire and waste disposal
Other
- Material Compatibility
- Processing & Application Methods
- Application Information
Value Units Test Method / Conditions Mix Ratio 1.92 %(W) Filler : Resin Mix Ratio 0.07 %(W) Flexibilizer : Resin Mix Ratio 1.0 %(W) Hardener : Resin