ARALDITE® LY 3585 / ARADUR® 3487

ARALDITE® LY 3585 / ARADUR® 3487 is used for industrial composites and warm warm-curing epoxy systems.

RTU Product Type: Laminating Resin System

Product End Uses: Industrial Composites

Chemical Family: Epoxy & Epoxy Derivatives

Composites Processing Methods: Filament Winding, Pressure Molding, Resin Transfer Molding (RTM), Seemans Composite Resin Injection Molding Process (SCRIMPSM), Wet Lay-Up

Features: Long Potlife

  • TypeDocument Name
View All Documents

Enhanced TDS

Identification & Functionality

Features & Benefits

Labeling Claims
Ready-to-Use Product Features
Product Properties
  • Reactive diluent free laminating system.
  • The reactivity may easily be adjusted to demands through the combination of both hardeners.
  • Aradur 3486 exhibits a very long pot life.

Applications & Uses

Composites Processing Methods
Product End Uses
Processing Information
  • Resin Transfer Moulding (RTM, SCRIMP)
  • Wet lay-up
  • Filament Winding
  • Pressure Moulding

Properties

Physical Form

Technical Details & Test Data

Processing Guidelines
Components Parts by weight Parts by volume
ARALDITE® LY 3585 100 100
ARADUR® 3487 32 40

 

  • We recommend that the components are weighed with an accurate balance to prevent mixing inaccuracies which can affect the properties of the matrix system.
  • The components should be mixed thoroughly to ensure homogeneity. It is important that the side and the bottom of the vessel are incorporated into the mixing process.
  • When processing large quantities of mixture the pot life will decrease due to exothermic reaction. It is advisable to divide large mixes into several smaller containers. 
Properties of The Cured, Neat Formulation
Property Key Value Unit Test method Condition
Glass Transition Temperature (LY 3585) 47 - 54 °C IEC 1006, DSC, 10 K/MIN 7 days 23°C
Glass Transition Temperature (LY 3585) 60 - 67 °C IEC 1006, DSC, 10 K/MIN 20 h 40°C
Glass Transition Temperature (LY 3585) 65 - 73 °C IEC 1006, DSC, 10 K/MIN 16 h 50°C
Glass Transition Temperature (LY 3585) 80 - 86 °C IEC 1006, DSC, 10 K/MIN 16 h 60°C
Glass Transition Temperature (LY 3585) 90 - 98 °C IEC 1006, DSC, 10 K/MIN 8 h 80°C
Glass Transition Temperature (LY 3585) 95 - 102 °C IEC 1006, DSC, 10 K/MIN 1 h 100°C
Glass Transition Temperature (LY 3585) 97 - 105 °C IEC 1006, DSC, 10 K/MIN 2 h 100°C
Glass Transition Temperature (LY 3585) 95 - 105 °C IEC 1006, DSC, 10 K/MIN 3 h 100°C
Glass Transition Temperature (LY 3585) 98 - 106 °C IEC 1006, DSC, 10 K/MIN 4 h 100°C
Glass Transition Temperature (LY 3585) 100 - 110 °C IEC 1006, DSC, 10 K/MIN 5 h 100°C
Glass Transition Temperature (LY 3585) 100 - 110 °C IEC 1006, DSC, 10 K/MIN 2 h 120°C
Glass Transition Temperature (LY 3585) 102 - 112 °C IEC 1006, DSC, 10 K/MIN 5 h 120°C
Glass Transition Temperature (LY 3585) 38 - 43 °C IEC 1006, DSC, 10 K/MIN 7 days 23°C
Glass Transition Temperature (LY 3585) 48 - 53 °C IEC 1006, DSC, 10 K/MIN 20 h 40°C
Glass Transition Temperature (LY 3585) 61 - 67 °C IEC 1006, DSC, 10 K/MIN 16 h 50°C
Glass Transition Temperature (LY 3585) 78 - 84 °C IEC 1006, DSC, 10 K/MIN 16 h 60°C
Glass Transition Temperature (LY 3585) 88 - 94 °C IEC 1006, DSC, 10 K/MIN 8 h 80°C
Glass Transition Temperature (LY 3585) 93 - 98 °C IEC 1006, DSC, 10 K/MIN 1 h 100°C
Glass Transition Temperature (LY 3585) 99 - 104 °C IEC 1006, DSC, 10 K/MIN 2 h 100°C
Glass Transition Temperature (LY 3585) 100 - 105 °C IEC 1006, DSC, 10 K/MIN 3 h 100°C
Glass Transition Temperature (LY 3585) 100 - 110 °C IEC 1006, DSC, 10 K/MIN 4 h 100°C
Glass Transition Temperature (LY 3585) 103 - 112 °C IEC 1006, DSC, 10 K/MIN 5 h 120°C
Glass Transition Temperature (LY 3585) 103 - 112 °C IEC 1006, DSC, 10 K/MIN 5 h 120°C
Torsional Test (LY 3585 / Aradur® 3487) 69 - 75 °C ISO 6721, DMA, 2K/MIN 15 h 50°C
Torsional Test (LY 3585 / Aradur® 3486) 77 - 83 °C ISO 6721, DMA, 2K/MIN 15 h 50°C
Tensile Strength (LY 3585 / Aradur® 3487) 70 - 80 MPa ISO 527 5 h 100°C
Elongation at Tensile Strength (LY 3585 / Aradur® 3487) 4.8 - 5.2 % ISO 527 5 h 100°C
Ultimate Strength (LY 3585 / Aradur® 3487) 70 - 80 MPa ISO 527 5 h 100°C
Ultimate Elongation (LY 3585 / Aradur® 3487) 6.0 - 7.0 % ISO 527 5 h 100°C
Tensile Modulus (LY 3585 / Aradur® 3487) 2950 - 3100 MPa ISO 527 5 h 100°C
Tensile Strength (LY 3585 / Aradur® 3486) 70 - 74 MPa ISO 527 5 h 100°C
Elongation at Tensile Strength (LY 3585 / Aradur® 3486) 5.5 - 6.5 % ISO 527 5 h 100°C
Ultimate Strength (LY 3585 / Aradur® 3486) 66 - 70 MPa ISO 527 5 h 100°C
Ultimate Elongation (LY 3585 / Aradur® 3486) 8.0 - 10 % ISO 527 5 h 100°C
Tensile Modulus (LY 3585 / Aradur® 3486) 2700 - 2900 MPa ISO 527 5 h 100°C
Flexural Strength (LY 3585 / Aradur® 3487) 130 - 140 MPa ISO 178 15 h 50°C
Elongation at Flexural Strength (LY 3585 / Aradur® 3487) 4.0 - 5.3 % ISO 178 15 h 50°C
Ultimate Strength (LY 3585 / Aradur® 3487) 105 - 120 MPa ISO 178 15 h 50°C
Ultimate Elongation (LY 3585 / Aradur® 3487) 7.0 - 8.0 % ISO 178 15 h 50°C
Flexural Modulus (LY 3585 / Aradur® 3487) 3400 - 3600 MPa ISO 178 15 h 50°C
Flexural Strength (LY 3585 / Aradur® 3487) 120 - 130 MPa ISO 178 5 h 100°C
Elongation at Flexural Strength (LY 3585 / Aradur® 3487) 5.8 - 6.5 % ISO 178 5 h 100°C
Ultimate Strength (LY 3585 / Aradur® 3487) 118 - 126 MPa ISO 178 5 h 100°C
Ultimate Elongation (LY 3585 / Aradur® 3487) 7.0 - 8.2 % ISO 178 5 h 100°C
Flexural Modulus (LY 3585 / Aradur® 3487) 3000 - 3200 MPa ISO 178 5 h 100°C
Flexural Strength (LY 3585 / Aradur® 3486) 128 - 138 MPa ISO 178 15 h 50°C
Elongation at Flexural Strength (LY 3585 / Aradur® 3486) 4.5 - 5.5 % ISO 178 15 h 50°C
Ultimate Strength (LY 3585 / Aradur® 3486) 75 - 87 MPa ISO 178 15 h 50°C
Ultimate Elongation (LY 3585 / Aradur® 3486) 7.0 - 11.0 % ISO 178 15 h 50°C
Flexural Modulus (LY 3585 / Aradur® 3486) 3200 - 3500 MPa ISO 178 15 h 50°C
Flexural Strength (LY 3585 / Aradur® 3486) 120 - 130 MPa ISO 178 5 h 100°C
Elongation at Flexural Strength (LY 3585 / Aradur® 3486) 6.5 - 7.5 % ISO 178 5 h 100°C
Ultimate Strength (LY 3585 / Aradur® 3486) 105 - 125 MPa ISO 178 5 h 100°C
Ultimate Elongation (LY 3585 / Aradur® 3486) 9.0 - 12.0 % ISO 178 5 h 100°C
Flexural Modulus (LY 3585 / Aradur® 3486) 2750 - 2950 MPa ISO 178 5 h 100°C
Fracture Toughness (K1C) (LY 3585 / Aradur® 3487) 0.80 - 0.95 MPa√m PM 258-0/90 5 h 100°C
Fracture Energy (G1C) (LY 3585 / Aradur® 3487) 190 - 220 J/m² PM 258-0/90 5 h 100°C
Fracture Toughness (K1C) (LY 3585 / Aradur® 3486) 0.9 - 1.02 MPa√m PM 258-0/90 5 h 100°C
Fracture Energy (G1C) (LY 3585 / Aradur® 3486) 250 - 300 J/m² PM 258-0/90 5 h 100°C
Water Absorption (LY 3585 / Aradur® 3487) 0.46 - 0.56 % ISO 62

10 days H₂O 23°C

Water Absorption (LY 3585 / Aradur® 3486) 0.45 - 0.55 % ISO 62

10 days H₂O 23°C

Properties of The Cured, Reinforced Formulation
Shear Strength (LY 3485 / Aradur® 3487) 55 - 60 MPa ASTM D 2344

1.5 h 90°C + 5 h 100°C

Shear Strength (LY 3485 / Aradur® 3486) 59 - 63 MPa ASTM D 2344

1.5 h 90°C + 5 h 100°C

Flexural Strength (LY 3485 / Aradur® 3487) 950 - 1150 MPa ISO 178

1.5 h 90°C + 5 h 100°C

Elongation at Flexural Strength (LY 3485 / Aradur® 3487) 2.45 - 1.65 % ISO 178

1.5 h 90°C + 5 h 100°C

Ultimate Strength (LY 3485 / Aradur® 3487) 950 - 1150 MPa ISO 178

1.5 h 90°C + 5 h 100°C

Ultimate Elongation (LY 3485 / Aradur® 3487) 2.50 - 2.70 % ISO 178

1.5 h 90°C + 5 h 100°C

Flexural Modulus (LY 3485 / Aradur® 3487) 37500 - 42500 MPa ISO 178

1.5 h 90°C + 5 h 100°C

Flexural Strength (LY 3485 / Aradur® 3486) 1000 - 1200 MPa ISO 178

1.5 h 90°C + 5 h 100°C

Elongation at Flexural Strength (LY 3485 / Aradur® 3486) 2.40 - 2.60 % ISO 178

1.5 h 90°C + 5 h 100°C

Ultimate Strength (LY 3485 / Aradur® 3486) 980 - 1180 MPa ISO 178

1.5 h 90°C + 5 h 100°C

Ultimate Elongation (LY 3485 / Aradur® 3486) 2.45 - 2.65 % ISO 178

1.5 h 90°C + 5 h 100°C

Flexural Modulus (LY 3485 / Aradur® 3486) 37000 - 42000 MPa ISO 178

1.5 h 90°C + 5 h 100°C

 

Note 

  • Short beam: Laminate comprising 12 layers unidirectional
  • E-glass fabric (425 g/m²)
  • Laminate thickness t = 2.8 - 3.0 mm
  • Fibre volume content: 59 - 62 % 

Safety & Health

First Aid Information
  • Contamination of the eyes by resin, hardener or mix should be treated immediately by flushing with clean, running water for 10 to 15 minutes.
  • A doctor should then be consulted. Material smeared or splashed on the skin should be dabbed off, and the contaminated area then washed and treated with a cleansing cream (see above).
  • A doctor should be consulted in the event of severe irritation or burns.
  • Contaminated clothing should be changed immediately. Anyone taken ill after inhaling vapours should be moved out of doors immediately. In all cases of doubt call for medical assistance.

Storage & Handling

Storage Conditions
  • Provided that Araldite® LY 3585 and Aradur® 3486 or Aradur® 3487 are stored in a dry place in their original, properly closed containers at the above mentioned storage temperatures they will have the shelf lives indicated on the labels.
  • Partly emptied containers should be closed immediately after use.
  • Araldite® LY 3585 which has crystallized and looks cloudy can be restored to its original state by heating to 60 - 80 °C.
Handling Information
Safety Precautions
Protective clothing Yes
Gloves Essential
Arm protectors

Recommended when skin contact likely

Goggles/safety glasses Yes
Respirator/dust mask Recommended
Skin Protection
Skin protection before starting

Apply barrier cream to exposed skin

Skin protection after washing

Apply barrier or nourishing cream

Cleansing of contaminated skin

Dab off with absorbent paper, wash with warm water and alkali-free soap, then dry with disposable towels. Do not use solvents

Clean shop requirements

Cover workbenches, etc. with light coloured paper. Use disposable breakers, etc.

Disposal of spillage

Soak up with sawdust or cotton waste and deposit in plastic-lined bin

Ventilation
Ventilation of workshop

Renew air 3 to 5 times an hour

Ventilation of workplace

Exhaust fans. Operatives should avoid inhaling vapours.