Enhanced TDS
Identification & Functionality
- Chemical Family
- RTU Product Type
- Technologies
- Product Families
Features & Benefits
- Product Features
- Features and Benefits
- Easy to apply
- Very high temperature resistance
- Does not drain off vertical surface
- Partial cure at room temperature completed with post cure indicated
Applications & Uses
- Markets
- Applications
- Application Information
- Pre-preg tools
- In combination with an appropriate laminating system to construct high temperature tools
Properties
- Physical Form
Technical Details & Test Data
- Mixed Ratio Information
Mix ratio Parts by weight RenGel©SW 5200 100 Ren©HY 5158 12.5 Mix the two components thoroughly in the ratio indicated.
Apply in thin layers with a brush or spatula, wait until gelcoat has gelled, but ensure that it is still slightly tacky before proceeding.
Post-curing will improve final properties.- Cured Properties
Resin/Hardener mix: Volume Unit SW 5200 / HY 5158 Appearance Black Pot life at 25°C 250 ml min 120 Demoulding time
h 7 days at RT or 14 hours at 40oC After cure: 14h gradually to 160°C
Density ISO 1183 g/cm³ 1.6 Hardness ISO 868 Shore D 90 Deflection Temperature ISO 75 °C 160 - 170 Abrasion Taber mm³/100U 45 - 50
Packaging & Availability
- Packaging Information
System SW 5200 HY 5158 Quantity and Weight 2 x 5kg 4 x 600gr Quantity and Weight 200 kg
Storage & Handling
- Storage and Handling Information
Store SW 5200 at a temperature between 2 and 8°C, in its original container. Quantities of materials for immediate use (up to 5 days) can be held at room temperature without risk of deterioration. Store HY 5158 in a closed container between 6 and 28°C.The products should be handled when in the temperature range of 20 - 25°C.
- Handling Precautions
Caution Our products are generally quite harmless to handle provided that certain precautions normally taken when handling chemicals are observed. The uncured materials must not, for instance, be allowed to come into contact with foodstuffs or food utensils, and measures should be taken to prevent the uncured materials from coming in contact with the skin, since people with particularly sensitive skin may be affected. The wearing of impervious rubber or plastic gloves will normally be necessary; likewise the use of eye protection. The skin should be thoroughly cleansed at the end of each working period by washing with soap and warm water. The use of solvents is to be avoided. Disposable paper (not cloth towels) should be used to dry the skin. Adequate ventilation of the working area is recommended.
Other
- Processing & Application Methods
- Application Information
Value Units Test Method / Conditions Mix Ratio 0.125 %(W) Hardener : Resin - Mechanical Properties
Value Units Test Method / Conditions Hardness 90.0 Shore D ISO 868 - Physical Properties
Value Units Test Method / Conditions Density 1.6 g/cm³ ISO 1183