- Casting or laminating resin for general mold and tool making.
- With appropriate fillers, also suitable for backing models and molds.
Technical Details & Test Data
- Processing Information
Processing
Resin Hardener Weight Proportions
RenLam® LY 1918 Ren® HY 956 100 : 45 Mix the two components thoroughly in the specified ratio, then impregnate each layer of fabric before applying it to build the laminate. Post-curing improves the final properties.
Resin/Hardener Mixture: Mixed Viscosity (mPa.s) Processing Time 500g Batch (minutes) Minimum Curing Time (Hours)
RenLam® LY 1918 : Ren® HY 956 1020 25 20 - 24 After curing, 7 days at room temperature or 14 hours at 40 °C
Molding Material of the Mixture RenLam® LY 1918 : Ren® HY 956
Density (g/cm³) 1.17 Shore Hardness D ISO 686 85 Compressive Strength ISO 604 (MPa) 116 Flexural Strength ISO 178 (MPa) 134 Impact Strength ISO 179 (kJ/m²) 28 Heat Resistance ISO 75 (°C) 67 Water Absorption 24 hours (%) 0.21 Water Intake 3 days (%) 0.34
Safety & Health
- Caution Measures
Our products can be processed safely, provided that the usual precautions for handling chemicals are observed.Uncured materials should be kept away from food. To avoid allergic reactions, it is strongly recommended to wear impermeable rubber or plastic gloves and safety goggles. Hands must be thoroughly washed with warm water and soap after each use. The use of solvents should be avoided. Afterwards, the skin should be dried with disposable paper towels – not textiles. The work area should be well ventilated; an extraction system above the workstation may be required. A description of all precautionary measures is included in the safety data sheets for the individual products. We will be happy to send these to you upon request.
Storage & Handling
- Storage Conditions
Provided that RenLam® LY 1918 and Ren® HY 956 are stored in a dry place.Partially emptied containers should be resealed immediately after use.The product should be processed in the temperature range 18-25°C.