- Product Features
- High thixotropic, suitable for the electrical component with gap(<0.3mm) to prevent leakage;
- Pass UL94 V0 (Halogen-free)
- Excellent thermal shock resistance
- Fast cure
Applications & Uses
- Composites Processing Methods
- Product End Uses
- Markets
- Applications
- Application Information
- Encapsulation of electrical ventilation switch, electrical component
- Especially Suitable for the electrical component with gap(<0.3mm) to prevent leakage.).
- Processing Information
- ARALDITE® CW2246 CI contain fillers, which tend to settle over time. It is therefore recommended to carefully homogenize the complete contents of the container before use. In the storage vessels of the production equipment, the pre-filled products should be stirred up from time to time to avoid sedimentation and irregular metering
- Using two component vacuum potting machine, resin should be stored into A barrel (40 - 60°C,vacuum 1 - 5mbar), hardener should be stored into B barrel (25 - 40°C, vacuum 2 - 10 mbar). When casting resin and hardener should have suitable metering pump and mixing machine.
- Before application, the mixed material should be degassed under (vacuum 2- 10 mbr) to have good quality casting. Void will affect thermal and electrical properties. After mixing, it will start to react under different temperature. The pot life will become shorter, please try to use the material quickly.
Properties
Regulatory & Compliance
- Certifications & Compliance
Technical Details & Test Data
- Typical Curing Properties
Typical curing properties: at 23°C cured for 6 hours at 60 °C
Temperature 41 °C ISO 11357-2 Hardness (Shore D) at 25°C 68 Shore D DIN 53505 Coefficient of linear thermal expansion (Below Tg) 45 ppm/K ISO 11359-2 Tensile Strength 19.8 MPa ISO 527 Flexural Strength 44 MPa ISO 178 Flexural Modulus 1.8 GPa ISO 178 Water absorption (100°C/30min) 0.35 % ISO 62 Water absorption (23°C/24h) 0.24 % ISO 62 Breakdown strength 25 kV/mm IEC 243-1
Storage & Handling
- Storage Conditions
- Store the components in a dry place, 5-35°C according to the storage conditions stated on the label in tightly sealed original containers.
- Under these conditions, the shelf life will correspond to the expiry date stated on the label.
- After this date, the product may be processed only after reanalysis.
- Partly emptied containers should be tightly closed immediately after use.
Other
- Application Information
Value Units Test Method / Conditions Mix Ratio 0.18 %(W) %(W) Hardener : Resin