ARALDITE® LY 1556 / REN® HY 5212

ARALDITE® LY 1556 / REN® HY 5212 is a hot curing epoxy system, ARALDITE® LY 1556 is an epoxy resin REN® HY 5212 is a formulated amine hardener, it has Industrial composites, Structural composites

RTU Product Type: Laminating Resin System

Product End Uses: Industrial Composites, Structural Composites

Chemical Family: Epoxy & Epoxy Derivatives

Composites Processing Methods: Filament Winding, Pressure Molding, Pultrusion, Resin Transfer Molding (RTM)

Cure Method: Heat Cure

  • TypeDocument Name
View All Documents

Enhanced TDS

Identification & Functionality

Applications & Uses

Composites Processing Methods
Cure Method
Product End Uses
Processing Information
  • Filament Winding
  • Resin Transfer Moulding (RTM)
  • Pressure Moulding
  • Pultrusion

Technical Details & Test Data

Processing Guidelines

Components Parts by weight Parts by volume ARALDITE® LY 1556 100 100 Ren® HY 5212 23 27

 

  • We recommend that the components are weighed with an accurate balance to prevent mixing inaccuracies which can affect the properties of the matrix system. The components should be mixed thoroughly to ensure homogeneity. It is important that the side and the bottom of the vessel are incorporated into the mixing process.
  • When processing large quantities of mixture the pot life will decrease due to exothermic reaction. It is advisable to divide large mixes into several smaller containers.
Properties of The Cured, Neat Formulation
Property Value Unit Test Method At Condition
Glass Transition Temperature 140 - 145 °C ISO 11357-2, DSC

4 h 80°C + 4 h 150°C

Glass Transition Temperature 140 - 148 °C ISO 11357-2, DSC

2 h 80°C + 4 h 160°C

Glass Transition Temperature 141 - 149 °C ISO 11357-2, DSC

2 h 80°C + 2 h 120°C + 4 h 150°C

Glass Transition Temperature 135 - 140 °C DMA, ISO 6721

2 h 80°C + 2 h 120°C + 4 h 150°C

Tensile Test 80 - 90 MPa ISO 527

2 h 80°C + 2 h 120°C + 4 h 150°C

Tensile Test 4.5 - 5.0 % ISO 527

2 h 80°C + 2 h 120°C + 4 h 150°C

Tensile Test 80 - 90 MPa ISO 527

2 h 80°C + 2 h 120°C + 4 h 150°C

Tensile Test 4.5 - 5.0 % ISO 527

2 h 80°C + 2 h 120°C + 4 h 150°C

Tensile Test 2800 - 2900 MPa ISO 527

2 h 80°C + 2 h 120°C + 4 h 150°C

Flexural Test 130 - 140 MPa ISO 178

2 h 80°C + 2 h 120°C + 4 h 150°C

Flexural Test 6.0 - 7.0 % ISO 178

2 h 80°C + 2 h 120°C + 4 h 150°C

Flexural Test 130 - 140 MPa ISO 178

2 h 80°C + 2 h 120°C + 4 h 150°C

Flexural Test 6.0 - 7.0 % ISO 178

2 h 80°C + 2 h 120°C + 4 h 150°C

Flexural Test 3000 - 3100 MPa ISO 178

2 h 80°C + 2 h 120°C + 4 h 150°C

Fracture Properties 0.60 - 0.65 MPa√m ISO 13586

2 h 80°C + 2 h 120°C + 4 h 150°C

Fracture Properties 140 - 150 J/m² ISO 13586

2 h 80°C + 2 h 120°C + 4 h 150°C

Properties of The Cured, Reinforced Formulation

Property Value Unit Test Method At Condition Interlaminar Shear Strength 55 - 56 MPa ASTM D 2344

2 h 80°C + 2 h 120°C + 4 h 150°C

 

Note

  • Short beam: Laminate comprising 12 layers unidirectional
  • E-glass fabric (425 g/m²)
  • Laminate thickness t = 3.1 - 3.3 mm
  • Fibre volume content: 63 - 65 % 

Safety & Health

First Aid Information
  • Contamination of the eyes by resin, hardener or mix should be treated immediately by flushing with clean, running water for 10 to 15 minutes. A doctor should then be consulted.
  • Material smeared or splashed on the skin should be dabbed off, and the contaminated area then washed and treated with a cleansing cream (see above).
  • A doctor should be consulted in the event of severe irritation or burns. Contaminated clothing should be changed immediately.
  • Anyone taken ill after inhaling vapours should be moved out of doors immediately. In all cases of doubt call for medical assistance.

Storage & Handling

Storage Conditions
  • Provided that Araldite® LY 1556 or Ren® HY 5212 are stored in a dry place in their original, properly closed containers at the storage temperatures mentioned in the MSDS they will have the shelf lives indicated on the labels.
  • Partly emptied containers should be closed immediately after use.
Handling Information
Safety Precautions
Protective clothing Yes
Gloves Essential
Arm protectors

Recommended when skin contact likely

Goggles/safety glasses Yes
Respirator/dust mask Recommended
Skin Protection
Skin protection before starting

Apply barrier cream to exposed skin

Skin protection after washing

Apply barrier or nourishing cream

Cleansing of contaminated skin

Dab off with absorbent paper, wash with warm water and alkali-free soap, then dry with disposable towels. Do not use solvents

Clean shop requirements

Cover workbenches, etc. with light coloured paper. Use disposable breakers, etc.

Disposal of spillage

Soak up with sawdust or cotton waste and deposit in plastic-lined bin

Ventilation
Ventilation of workshop

Renew air 3 to 5 times an hour

Ventilation of workplace

Exhaust fans. Operatives should avoid inhaling vapours.