Enhanced TDS
Identification & Functionality
- Chemical Family
- RTU Product Type
- Technologies
- Product Families
Features & Benefits
- Ready-to-Use Product Features
- Product Features
- High Tg anhydride-cured, toughened system with good compromise between in-mould pre-cure capability and colour for aesthetic carbon look applications
 
Applications & Uses
- Composites Processing Methods
- Cure Method
- Processing Information
- RTM / HP-RTM
 
Properties
- Notes
- 1 part DY 079 - 40 min 120° C + 2 h 190 °C
- 2 parts DY 079 - 20 min 120° C + 2 h 190 °C
 
Technical Details & Test Data
- Processing Guidelines
- Components - Parts by weight - Parts by volume - ARALDITE® LY 1560 - 100 - 100 - ARADUR® 917 - 90 - 118 - ACCELERATOR DY 079 - 2 - 5 - 1 - 2 - We recommend that the components are weighed with an accurate balance to prevent mixing inaccuracies which can affect the properties of the matrix system.
- The components should be mixed thoroughly to ensure homogeneity. It is important that the side and the bottom of the vessel are incorporated into the mixing process.
 
- Properties of The Cured, Neat Formulation
- Property - Value - Unit - Test Method - At Condition - Glass Transition Temperature - 195 – 205 - °C - ISO 11357-2, DSC - 5K/MIN - Glass Transition Temperature - 185 – 195 - °C - DMA ISO 6721, DSC - 2K/MIN - Tensile Test Tensile strength - 70 – 80 - MPa - ISO 527 - Tensile Test Elongation at tensile strength - 4.0 – 5.0 - % - ISO 527 - Tensile Test Tensile modulus - 2550 – 2700 - MPa - ISO 527 - Fracture Properties Fracture toughness K1C - 0.80 – 0.90 - MPa√m - ISO 13586 - Fracture Properties Fracture energy G1C - 230 – 280 - J/m² - ISO 13586 
Safety & Health
- First Aid Information
- Contamination of the eyes by resin, hardener or mix should be treated immediately by flushing with clean, running water for 10 to 15 minutes.
- A doctor should then be consulted. Material smeared or splashed on the skin should be dabbed off, and the contaminated area then washed and treated with a cleansing cream (see above).
- A doctor should be consulted in the event of severe irritation or burns.
- Contaminated clothing should be changed immediately. Anyone taken ill after inhaling vapours should be moved out of doors immediately. In all cases of doubt call for medical assistance.
 
Storage & Handling
- Storage Conditions
- Provided that Araldite® LY 1560, Aradur® 917 and Accelerator DY 079 are stored in a dry place in their original, properly closed containers at the storage temperatures mentioned in the MSDS they will have the shelf lives indicated on the labels.
- Partly emptied containers should be closed immediately after use. Because Aradur® 917 is sensitive to moisture, storage containers should be ventilated with dry air only.
 
- Handling Information
- Safety Precautions - Protective clothing - Yes - Gloves - Essential - Arm protectors - Recommended when skin contact likely - Goggles/safety glasses - Yes - Respirator/dust mask - Recommended - Skin Protection - Skin protection before starting - Apply barrier cream to exposed skin - Skin protection after washing - Apply barrier or nourishing cream - Cleansing of contaminated skin - Dab off with absorbent paper, wash with warm water and alkali-free soap, then dry with disposable towels. Do not use solvents - Clean shop requirements - Cover workbenches, etc. with light coloured paper. Use disposable breakers, etc. - Disposal of spillage - Soak up with sawdust or cotton waste and deposit in plastic-lined bin - Ventilation - Ventilation of workshop - Renew air 3 to 5 times an hour - Ventilation of workplace - Exhaust fans. Operatives should avoid inhaling vapours. 
Other
- Application Information
- Value - Units - Test Method / Conditions - Mix Ratio - 0.01-0.02 %(W) - %(W) - Accelerator : Resin - Mix Ratio - 1.18 %(W) - %(W) - Hardener : Resin