ARALDITE® MY 740 / ARALDITE® F / ARADUR® HY 2918 / ARADUR® HY 905 / DY 062

ARALDITE® MY 740 / ARALDITE® F / ARADUR® HY 2918 / ARADUR® HY 905 / DY 062 is a Casting system for processing at room temperature or slightly higher temperature. Curing at high temperature. By addition of an appropriate amount of ACCELERATOR DY 062 the casting resin system may be optimally adjusted to particular applications

RTU Product Type: Casting Resin

Product End Uses: Electrically Insulating Components

Chemical Family: Epoxy & Epoxy Derivatives

Composites Processing Methods: Casting, Encapsulation, Potting, Vacuum Pressure Impregnation (VPI)

Features: Excellent Dielectric Properties, Good Mechanical Properties, Improved Ageing Resistance

Cure Method: Heat Cure

  • TypeDocument Name
View All Documents

Enhanced TDS

Identification & Functionality

Features & Benefits

Applications & Uses

Composites Processing Methods
Cure Method
Product End Uses
Processing Methods

Conventional casting, or vacuum impregnating

Application Information

Encapsulating or potting of low-voltage and electronic components

Properties

Physical Form
Product Data

Araldite® MY 740

 

Property Key Value Unit Test Method Condition
Viscosity (Hoeppler) 10,000 - 14,500 mPa s ISO 12058 at 25°C
Specific gravity 1.16 g/cm³ ISO 1675 at 25°C
Flash point > 200 °C ISO 1523  
Epoxy content 5.25 - 5.55 Eq/kg ISO 3001  
Vapour pressure (at 20°C) < 0.5 Pa Knudsen at 20°C
Vapour pressure (at 60°C) < 0.01 Pa Knudsen at 60°C

 

Araldite® F

Property Key Value Unit Test Method Condition
Viscosity (Hoeppler) 9,000 - 12,000 mPa s ISO 12058 at 25°C
Specific gravity 1.15 - 1.20 g/cm³ ISO 1675 at 25°C
Flash point > 200 °C ISO 1523  
Epoxy content 5.10 - 5.30 Eq/kg ISO 3001  

 

Aradur® HY 2918

Property Key Value Unit Test Method Condition
Viscosity (Hoeppler) 50 - 80 mPa s ISO 12058 at 25°C
Specific gravity 1.2 g/cm³ ISO 1675 at 25°C
Flash point > 140 °C ISO 1523 at 25°C

 

Aradur® HY 905

Property Key Value Unit Test Method Condition
Viscosity 150 - 200 mPa s ISO 12058 at 25°C
Specific gravity 1.2 g/cm³ ISO 1675 at 25°C
Flash point 150 °C ISO 1523 at 25°C

 

Accelerator DY 062

Property Key Value Unit Test Method Condition
Viscosity (Epprecht TV) 10 mPa s ISO 12058 at 25°C
Specific gravity 0.9 g/cm³ ISO 1675 at 25°C
Flash point 59 °C ISO 1523 at 25°C

"

Technical Details & Test Data

Cured Properties

Condition : Guideline values determined on standard test specimens Cured for 2 h/80°C and 2h/120°C

 

Property Value 1 Value 2 Value 3 Unit Test Method
Shore D hardness (4 mm plate) 76 73 75   DIN 53 505
Glass Transition Temperature 123 109 108 °C ISO11357
Tensile strength 61 88 90 MPa ISO 527
Elongation at break 2 4 4 % ISO 527
Elastic modulus 3637 3436 3490 MPa ISO 527
Water Absorption (10 days at 23°C) 0.28 0.25 0.25 % ISO 62
Water Absorption (30 min at 100°C) 0.05 0.05 0.16 % ISO 62
Dielectric constant (50 Hz) at 23°C 3.3 3.2 3.2   IEC 60250
Dielectric constant at 60°C 3.3 3.2 3.3   IEC 60250
Dielectric constant at 80°C 3.3 3.3 3.3   IEC 60250
Dielectric constant at 100°C 3.4 3.4 3.4   IEC 60250
Dissipation factor tan (50 Hz) at 23°C 0.1 0.1 0.1 % IEC 60250
Dissipation factor tan at 60°C 0.1 0.1 0.1 % IEC 60250
Dissipation factor tan at 80°C 0.1 0.1 0.1 % IEC 60250
Dissipation factor tan at 100°C 0.3 0.8 0.8 % IEC 60250
Volume resistivity at 23°C 3x1016 3x1016 6x1016 cm IEC 60093
Volume resistivity at 60°C 2x1016 2x1016 3x1016 cm IEC 60093
Volume resistivity at 80°C 1x1016 6x1015 9x1015 cm IEC 60093
Volume resistivity at 100°C 1x1015 6x1014 1x1015 cm IEC 60093
Electrolytic corrosion A-1 A-1 A-1   IEC 60426
Tracking resistance >600 >600 >600 CTI IEC 60112
Electric strength (20 s for 2 mm plate, 50 Hz at 23°C ) 19 19 19 kV/mm IEC 60243
Product Properties
  • Good mechanical and dielectric properties
  • Good ageing resistance
Processing Guidelines

Minimum curing time 2h 80°C + 2h 120°C

System   1 2 3
Initial viscosity (Hoeppler)
at 25°C mPa s 950 1510 2125
at 60°C mPa s 70 120 150
Pot life (Hoeppler)
to 1500 mPa s at 60°C h 31/4 21/2 31/2
to 15 000 mPa s at 25°C h >50 >30 >32

Safety & Health

Disposal

Regular procedures approved by national and/or local authorities

Handling Precautions
Personal hygiene
Safety precautions at workplace
protective clothing overalls
gloves essential
arm protectors recommended when skin contact likely
goggles/safety glasses yes
Skin protection
before starting work Apply barrier cream to exposed skin
after washing Apply barrier or nourishing cream
Cleansing of contaminated skin Dab off with absorbent paper, wash with warm water
and alkali-free soap, then dry with disposable towels.
Do not use solvents
Disposal of spillage Soak up with sawdust or cotton waste and deposit in
plastic-lined bin
Ventilation of workshop Renew air 3 to 5 times an hour
Ventilation of workplaces Exhaust fans. Operatives should avoid inhaling
vapours

First Aid : Contamination of the eyes by resin, hardener or mix should be treated immediately by flushing with clean, running water for 10 to 15 minutes. A doctor should then be consulted. Material smeared or splashed on the skin should be dabbed off, and the contaminated area then washed and treated with a cleansing cream (see above). A doctor should be consulted in the event of severe irritation or burns. Contaminated clothing should be changed immediately. Anyone taken ill after inhaling vapours should be moved out of doors immediately. In all cases of doubt call for medical assistance.

Storage & Handling

Storage Conditions

Store the components at 18-25°C, in tightly sealed and dry original containers. Under these conditions, the shelf life will correspond to the expiry date stated on the label. Product specific advise regarding storage can be found on product label. After this date, the product December be processed only following reanalysis. Partly emptied containers should be closed tightly immediately after use.