DALTOPIR® XHFR

DALTOPIR® XHFR is commonly used in combination with SUPRASEC® 2085 polymeric MDI, to produce high index PIR foam for the manufacturing of composite panels by a continuous lamination process. The polyol blend contains up to 20% recycled content as defined in ISO 14021 and can allow for smooth foam processing and reduced foam friability like conventional Huntsman composite panel systems.
Brochure
  • TypeDocument Name
View All Documents

Enhanced TDS

Identification & Functionality

Blend
No
Chemical Family
Function
Resin,Insulating Agent
Single Ingredient
Yes

Features & Benefits

Labeling Claims
Ready-to-Use Product Features
Product Feature
  • When combined with a suitable process and panel design, the resulting composite panel with this specific PIR foam core can help panel producers to achieve both Reaction to fire and Resistance to fire classifications.
  • To help with long term adhesion and durability, the use of a primer is recommended.
  • Halogen-free formulation concept, with superior fire properties and low smoke emission
  • Up to 20% recycled content in polyol blend (4-5.5% in the foam at 100 mm thickness, ratio dependent).
  • Smooth and solid foam processing
  • Reduced foam friability
  • Very good top surface quality
  • Low thermal conductivity
  • Good physical properties and low lambda values, at typical densities
  • Fast productivity
  • Good bottom adhesion and durability (in combination with suitable primer, like DALTOPIR™ PRIM primer)
  • Can help to achieve Bs1d0 and (R)EI30 (EN 1364-1, EN 1365-2) requirements.
Product Advantages
  • Commercial and industrial buildings
  • Roofs and walls
  • Commercial and residential entry and garage door panels
  • Commercial refrigeration

Applications & Uses

Properties

Fire and Smoke Properties

When combined with a suitable process and panel design, the following certifications can be achieved:

Property Standards PIR foam Composite panels

Construction elements

Reaction to fire EN 13501-1, EN ISO 11925-2 Class E    
Reaction to fire

EN 13501-1, EN 13823

  Bs1d0  
Fire resistance (100 mm)

EN 1364-1, EN 1365-2

    EI 30

Packaging & Availability

Regional Availability
  • EIMEA

Other

Processing & Application Methods
Thermal Properties
ValueUnitsTest Method / Conditions
Thermal Conductivity19.0-21.0 mW/m.KmW/m.KAt 10°C
Mechanical Properties
ValueUnitsTest Method / Conditions
Compressive Strength120.0-180.0 kPakPaEN 826
Tensile Strength100.0-160.0 kPakPaEN 1607