Enhanced TDS
Identification & Functionality
- Chemical Family
- RTU Product Type
- Technologies
- Product Families
Features & Benefits
- Ready-to-Use Product Features
- Product Features
- Rapid setting paste
- 1:1 mixing ratio
Applications & Uses
- Markets
- Applications
Properties
- Physical Form
Technical Details & Test Data
- Processing Information
Mix Ratio
Product Parts by weight Parts by volume FASTWELD 10 A 100 1 FASTWELD 10 B 100 1 - Mix only that quantity which can be applied immediately after mixing.
- Due to the very fast setting properties of Fastweld 10, hand mixing of the components should be avoided.
- FASTWELD 10 is available in 50 mL twin cartridges.
- For best results, Fastweld 10 should be dispensed using manual or pneumatic dispensing equipment through a 0.25 in diameter, 20 element static mixing nozzle (Nordson EFD #7701488 or equivalent).
- For other mixing and application recommendations, please consult your local Huntsman Advanced Materials representative or one of our distributors.
Processing Data
Parameter Value Pot life, 2 fl oz at 25 °C, min 3 - 4 Typical cure cycle 4 h at 25°C, curing at elevated temperatures is not recommended Typical Physical Properties
Unless otherwise stated, the data were determined with typical production batches using standard test methods. They are typical values only, and do not constitute a product specification. The figures below were all determined by testing standard specimens made up by lap-joint 4 in x 1 in x 0.06 in (10 cm x 2.5 cm x 1.5 mm) strips of degreased and 100-grit abraded aluminum. The joint area was 0.5 x 1 in (12.5 mm x 2.5 cm) in each case. Samples were cured for 24 h at 77°F (25°C), unless a different cure is specified.
Property Value Tensile lap shear at 25°C, psi (MPa)
Cure: 1 h 41°F (5°C)1,420 (10) Tensile lap shear at 25°C, psi (MPa)
Cure: 4 h 41°F (5°C)1,560 (11) Tensile lap shear at 25°C, psi (MPa)
Cure: 24 h 41°F (5°C)1,710 (12) Tensile lap shear at 25°C, psi (MPa)
Cure: 30 min 77°F (25°C)1,710 (12) Tensile lap shear at 25°C, psi (MPa)
Cure: 1 h 77°F (25°C)2,130 (15) Tensile lap shear at 25°C, psi (MPa)
Cure: 4 h 77°F (25°C)2,840 (20) Tensile lap shear at 25°C, psi (MPa)
Cure: 24 h 77°F (25°C)2,840 (20) Tensile lap shear;* psi (MPa)
Test temperature: -40°F (-40°C)1,560 (11) Tensile lap shear;* psi (MPa)
Test temperature: 77°F (25°C)2,840 (20) Tensile lap shear;* psi (MPa)
Test temperature: 104°F (40°C)2,420 (17) Tensile lap shear;* psi (MPa)
Test temperature: 140°F (60°C)1,140 (8) Tensile lap shear, exposure to 120°F (49°C) / 95 % R.H., psi (MPa)
0 day2,840 (20) Tensile lap shear, exposure to 120°F (49°C) / 95 % R.H., psi (MPa)
10 days1,710 (12) Tensile lap shear, exposure to 120°F (49°C) / 95 % R.H., psi (MPa)
30 days1,000 (7) Tensile lap shear, heat aging at 140°F (60°C), psi (MPa)
0 day2,840 (20) Tensile lap shear, heat aging at 140°F (60°C), psi (MPa)
10 days2,840 (20) Tensile lap shear, heat aging at 140°F (60°C), psi (MPa)
30 days2,990 (21) Tensile lap shear, heat aging at 140°F (60°C), psi (MPa)
60 days2,560 (18) Note: *Load applied 10 minutes after specimens reach test temperature.
Safety & Health
- Safety Information
keep out of reach of children
Storage & Handling
- Storage Conditions
- FASTWELD 10 A/B should be stored in a dry place in the original sealed containers, at temperatures between 2°C and 40°C (36°F and 104°F).
- Under these storage conditions, and when supplied under Huntsman standard certification, the product has a shelf life of 3 years (from date of manufacture).
- The product should not be exposed to direct sunlight.
- If stored below 60°F, the adhesive should be brought to 60°F - 77°F and conditioned at this temperature for some time prior to use.
Other
- Physical Properties
Value Units Test Method / Conditions Density 1.46 g/cm³ g/cm³ ASTM D792 at 25°C Viscosity 250000.0 cPs cPs ASTM D2393 at 25°C